EU-Förderung (3.909.708 €): WIEDERHERSTELLUNG DER KARDIALEN MECHANISCHEN FUNKTION DURCH POLYMERES KÜNSTLICHES MUSKELGEWEBE Hor 02.07.2020 EU-Rahmenprogramm für Forschung und Innovation "Horizont"

Auf einen Blick

Text

WIEDERHERSTELLUNG DER KARDIALEN MECHANISCHEN FUNKTION DURCH POLYMERES KÜNSTLICHES MUSKELGEWEBE

Heart Failure (HF) and Atrial Fibrillation (AF) are both associated with impairment of cardiac mechanical function. To assist ventricular contractility in HF, left ventricular assist devices (LVADs) have been developed and demonstrated able to reduce mortality in patients awaiting transplantation, but enormous disadvantages largely limit their long-term use. In parallel, promising devices to mechanically assist atrial contractile function have been successfully tested in large animals but never reached the clinical use. Our revolutionary idea to solve these clinical challenges is to exploit smart materials to support or restore the cardiac mechanical function. Among smart materials, liquid crystalline elastomers (LCEs) are able to respond to external stimuli in a reversible manner to generate movement or tension. The REPAIR consortium has recently developed a novel LCE-based artificial muscle that under external light stimulation is able to enhance cardiac muscle contraction. These results pave the way for the development of a novel generation of cardiac assist devices. We will first develop a mechanical performant and energetically efficient LCE material that, integrated with light sources (µLED array), will result in fundamental biomimetic contractile units to be structured in a suturable, remote controlled contractile tissue. The LCE-µLEDs contractile tissue will be exploited to develop a new generation of cardiac assist devices (e.g. ventriculoplasty patches, aortic rings for diastolic counterpulsation and epicardial bundles for atrial contraction assistance) and test the effects of their acute implantation in large mammals (open-chest sacrifice experiments) and human explanted hearts. Among LCE-device features: they will be self-contracting, low weight, associated with low thromboembolic risk, and most importantly, they will rely on a control unit that can modulate the exerted force providing the fist “tunable” cardiac assist device ever developed.


Geförderte Unternehmen:

Firmenname Förderungssumme
Bico Group AB 270.000 €
Centre Hospitalier Universitaire Vaudois 65.552 €
Consiglio Nazionale Delle Ricerche 280.000 €
Fondazione Toscana Gabriele Monasterio Per LA Ricerca Medica E Di Sanita Pubblica 0,00 €
Medtronic Bakken Research Center B.V. 502.969 €
Scuola Superiore Di Studi Universitari E Di Perfezionamento S Anna 350.000 €
Specific Polymers 0,00 €
Szegedi Tudomanyegyetem 230.000 €
Technische Universiteit Delft 301.470 €
Universita Degli Studi Di Firenze 1.077.567 €
Universiteit Maastricht 570.000 €

Quelle: https://cordis.europa.eu/project/id/952166